Work with white asbestos (chrysotile) and AIB was banned asbestos eventually building materials in the UK in the 1990s. From 2006, when the control of asbestos regulations was introduced as a comprehensive health and safety regulations, it can be assumed that asbestos awareness for the highest risk within the asbestos management industry is setting the control limits most to implement.


Control limit refers to the maximum number of asbestos fibres which an employee may suspend while working with asbestos without using specialized breathing apparatus. Different periods of exposure are calculated to ensure that short-term or long-term exposure is dangerous.


Memories of the dangers of white asbestos still exists in many areas, especially school before the 1970s, built in the early of 1980s, surface if asbestos compensation cases by an attorney asbestosis and a suffering of partner or survivors family member Court regularly. Former employees who are known, against breathing in the air received any advice or protection fibres, are diagnosed with asbestos-related diseases at the point when the Mesothelioma or asbestosis as 50 years appear so late symptoms after the time of exposure first.


Asbestos management consists of today rigorous training to ensure staff aware if you will be exposed and preventive measures are necessary to avoid exposure. The company employers also licensed or accredited and will show that you regularly air tests implementation and precise exposure records.


The legislation gives clear instructions that apply to all other employees of asbestos containing materials (ACMs) at work due to a construction and demolition waste are exposed to the same training procedures. You should also know how you encounter decontamination of exposure. When high-risk ACMs are known in the workspaces exist should then air testing be done to ensure that each fibre release within limits.


Also exposed to the prevention of workers, asbestos, exceeding the control limits applies to asbestos workers (such as surveying and asbestos strippers) and all other work situations where staff are known to work in close proximity of asbestos containing materials (ACM) i.e. plumbers, electricians and roofing.


Exposure to asbestos is measured by testing the air of the working area. Air is drawn through a filter in a specialized air pump and asbestos analyst then counts the number of fibres available. The analyst can therefore calculate the concentration of asbestos in the air.


Over 10 minutes to find 20 millilitres (ml) of air extracting 200 fibres (f) is the concentration than 10 fibres per Mililitre a pump in 10 minutes (total fibres/total millilitres expressed as 20f/ml) calculated.


Exposure to asbestos of control limits


Asbestos type 4 HR 10 min 12 week


Chrysotile only 0.3 f / ml 0.9 f / ml 72 fibre hrs / ml2 *.


Any other 0.2 f / ml 0.6 f / ml 48 fibre hrs / ml2 *.


* Total claims more than 12 weeks